Nonin 8000J-WO2 Adult Flex Sensor for WristOx and Avant 4000

SKU
8000J-WO
Quick Overview
Shorter 12 inch cable built for use with the WristOx 3100 or 3150 or Avant 4000.
$126.00

With a shorter 12 inch cable, the Nonin 8000J-WO2 is built for use with the WristOx 3100 or 3150 as well as with the Avant 4000 wireless pulse oximeter. Each sensor includes 25 disposable Flexiwraps.

Sensor Description: Adult flex

Patient Weight: Greater than 44lb or 20kg

Preferred Placement: Index, middle or ring finger

Recommended Applications:

  • extended duration
  • motion situations
  • for adults

Notes: Flex sensors must be stabilized on the patient using either Velcro-type wraps or medical tapes.

More Information
Tech Specs

 

Sensor Description

Model Number, Price

Patient Weight Range

Preferred Sensor Placement

Applications

Adult Articulated Finger Clip

8000AA-1
(3' cable)
8000AA-3
(9' cable)

Greater than 66lb or 30kg

Index, middle or ring finger

  • spot checking

  • short-term continuous use

  • for adults or adolescents

Adult Finger Clip

8000K2

Greater than 66lb or 30kg

Index, middle or ring finger

  • spot checking

  • short-term continuous use

  • for adults or adolescents

Pediatric Finger Clip

8000AP-1
(3' cable)
8000AP-3
(9' cable)

Greater than 18lb or 8kg

Index, middle or ring finger

  • spot checking

  • short-term continuous use

  • for children or small adults

Ear Clipa

8000Q

Greater than 88lb or 40kg

Ear lobe

  • spot checking

  • short-term continuous use

  • stress testing

Reflectancea

8000R

Greater than 66lb or 30kg

Middle of forehead

  • continuous monitoring

  • stress testing

Adult Flexb

8000J

Greater than 44lb or 20kg

Index, middle or ring finger

  • extended duration

  • motion situations

  • for adults

Infant Flexb

8008J

4 to 44lb,
2 to 20kg

Great toe

  • extended duration

  • motion situations

  • for infants

Neonatal Flexb

8001J

Less than 4lb or 2kg

Lateral aspect of foot

  • extended duration

  • motion situations

  • for neonates

NOTES:

  • These reusable sensors can be cleaned with isopropyl alcohol or sterilized with ethylene oxide (cold cycle).
  • Short-term continuous monitoring is defined as 30 minutes or less in duration.
  • Reflectance Sensors and Ear Clip Sensors generally do not perform as well as sensors located on the fingers or toes, and are not recommended for applications where the best possible accuracy is important.
  • b The Flex Sensors must be stabilized on the patient using either Velcro-type wraps or medical tapes.